91琪琪在线观看,五月婷综合久久,澳门免费视频1区,人妻无码一二三区

TR-900Your current location:Home > TR-900
TR-900J Multi-Parameter Patient Monitor
Release time:2015-07-10 Author:admin Source:

 

 

◆7 inch color TFT LCD display with high resolution.
◆For Adult, pediatrics and neonates.
◆All lead ECG can be stored,  100 VPC waveform recall
◆Intelligent pressure oscillation, import parts, high precision
measurement, safety, and has over-voltage protection.
◆Freezing, and 72 hours trend chart and alarm function, 1000 NIBP
measurement data storage. With the alarm playback function,
playback before and after the alarm four seconds, eight seconds or 16
seconds of the relevant waveform. Show the waveform of the recent
data of 1 hour recalling waveform , all data can be stored down. Six
kinds of optional interface : large font interface, standard interface,
all lead ECG interface, respiratory oxygenation interface, trend chart
interface , blood pressure trend interface. Alarm classification
function.
◆Universal platform design, easy software upgrades, can connect
with information workstation and compose to center information
workstation.
◆Built-in storage battery and recorder.
◆ISO 9001:2000,ISO 13485:2003 certificate
.
ECG              Lead configuration: standard 3 leads RA, LA, LL,  
                       Lead mode: I, II, III  5 leads cable RA, LA, LL, RL, V, 
                       Lead mode: I,II,III,aVR,aVL,aVF,V
                       Gain : 0.25,0.5,1,2
                       Heart Rate range : 20 ~ 230bpm (beat/min)
                       Accuracy:  ±1% or ±1bpm, choosing the bigger one
 

                       Resolution: 1 bpm (beat/min)
                       Sensitivity: > 200 uV
                       Input impedance : > 5MΩ
  NIBP           Measurement time in continuous mode: 5 minutes
                       Range of pulse rate: 40-240bpm
                       Scope of measurement and accuracy:
                       Adult   Systolic pressure    50~240mmHg
                       Diastolic pressure   30~200mmHg
                       Mean pressure     22~180mmHg
                       Static state pressure range    0~300mmHg
                       Static state pressure accuracy:  ±3mmHg
                       Accuracy of blood pressure : maximum average error
                      ±5mmHg;maximum standard deviation  8mmHg
                       Protection of over pressure: Adult      300mmHg
                                                                             Pediatrics   240mmHg
                                                                             Neonate    150mmHg
SPO2            Range of SPO2: 40%~100%
                       Resolution of SPO2: 1%
                       Accuracy of SPO2 : ≤±2%(90~99%)、≤±4%(70%~89%)、
                                                       ≤±6%(50%~69%)


 

Coopyright 2015 www.thewaterentrepreneurs.com Tianrong medical communication equipment Co., Ltd. All Rights Reserved
Company address: 21-1 Yangshan Road, Xuzhou Economic development zone, xuzhou city, jiangsu province, china, 24 hour Hotline :+86-13395229510 telephone :+86-516-85532818 E-mail : LB@tianrong.cn